Is the content displayed on the box the same?

Firstly Wrong network port plugged in
(1) Confirm that the Ethernet cable is plugged into the output port 1 of the sending card;
(2) Try broadcasting the network cable to another network port.
Secondly Resend display screen connection
Open NovaLCT Mars user ->Advanced user login ->666 (password) ->Display screen configuration ->Next ->Display screen connection ->Load from file ->Select corresponding SCR parameters ->Send to hardware ->Curing. Note: Before curing, be sure to check if the display screen is working properly. If so, click on curing.

Firstly Check the receiving card
(1) Check the power indicator light of the receiving card;
① Normal illumination, the receiving card is powered on;
② Not lit, check the switch power supply;
(2) Check the power indicator light of the switch power supply;
① Normal illumination, power supply working properly;
② Not working, replace the switch power supply;
③ If multiple power sources do not light up, check the wiring terminals;
④ When replacing the power supply or wiring terminals, it is necessary to cut off the power to avoid electric shock.
Secondly Replace short/long Ethernet cables
Replace the network cable of the current receiving card;
(2) Replace the Ethernet cable between the aircraft seat and the receiving card in the box
Thirdly Replace the receiving card
Replace the current receiving card;
(2) Please refer to “How to Send and Receive Card Parameters” for sending and receiving card parameters
Fourth Replace the adapter board
Replace the adapter board;
(2) Poor connection between the adapter board and the receiving card, improper insertion, and reverse insertion